Usage:
						Add 200g per ton water of this product 
						into boiler make-up water. During operation, blow-off 
						every hour, 5-10 second each time. If the boiler has 
						heavy scale, increase the quantity, and frequently 
						blow-off. After 10-20 days' continuous operation, stop 
						the boiler, open the handhole, remove the visible scale 
						deposit to prevent conduit blockage, then, the boiler 
						may turn into normal operation again.
					
					TH-503     
						would be better if the condense index of boiler water 
						was controlled within 10. Other parameters may refer to 
						related regulations (boiler water pH10-12, for example). 
						pH value should not be lower than 7. 
						The material of medicate tank should be 
						in plastic, concrete tank should be pretreated by 
						anticorrosion method, otherwise, it will be eroded by 
						the medicine, and the hardness will be increased much 
						high. 
						Total hardness of boiler make-up water 
						should be lower than 200mg/L. Once too high hardness is 
						countered, lime or other methods should be used to lower 
						it . 
						
						Package and Storage:
						200L plastic drum,IBC(1000L),customers’ requirement. Storage in shady room and dry place for one year.
						Safety Protection:
						Though no toxic, this product is acidic 
						and corrosive, once contacted with skin, flush with 
						water.